EI30-10.5 1.0VA Encapsulated Power Transformer

EI30-10.5-1.0VA

Encapsulated Power Transformer

               

GET QUOTE NOW! sales@tigermagnetics.com

  • Safety transformer/Short-circuit-proof
  • Vacuum Filled Casting
  • Split Bobbin Design
  • Temperature Class ta 70ºC/B
  • Dielectric Strength 4500Vrms
  • Weight:70 grams




PART NOPrimary [V]Secondary [V]Current [mA]PinNo-Load Voltage [V]Schematic No.
TG3010-E-0100-060-S230v~6166.61+5/7+98.21
TG3010-E-0100-090-S230v~9111.11+5/7+912.31
TG3010-E-0100-120-S230v~1283.31+5/7+916.41
TG3010-E-0100-150-S230v~1566.61+5/7+920.51
TG3010-E-0100-180-S230v~1855.51+5/7+924.61
TG3010-E-0100-240-S230v~2441.61+5/7+932.81
TG3010-E-0100-060-D230v~2× 62×83.31+5/6+7-9+102×8.22
TG3010-E-0100-075-D230v~2× 7.52×66.61+5/6+7-9+102×10.32
TG3010-E-0100-090-D230v~2× 92×55.51+5/6+7-9+102×12.32
TG3010-E-0100-120-D230v~2×122×41.61+5/6+7-9+102×16.42
TG3010-E-0100-150-D230v~2×152×33.31+5/6+7-9+102×20.52
TG3010-E-0100-180-D230v~2×182×27.71+5/6+7-9+102×24.62
TG3010-E-0100-240-D230v~2×242×20.81+5/6+7-9+102×32.82
TG3010-U-0100-060-S115v~6166.61+5/7+98.21
TG3010-U-0100-090-S115v~9111.11+5/7+912.31
TG3010-U-0100-120-S115v~1283.31+5/7+916.41
TG3010-U-0100-150-S115v~1566.61+5/7+920.51
TG3010-U-0100-180-S115v~1855.51+5/7+924.61
TG3010-U-0100-240-S115v~2441.61+5/7+932.81
TG3010-U-0100-060-D115v~2× 62×83.31+5/6+7-9+102×8.22
TG3010-U-0100-075-D115v~2× 7.52×66.61+5/6+7-9+102×10.32
TG3010-U-0100-090-D115v~2× 92×55.51+5/6+7-9+102×12.32
TG3010-U-0100-120-D115v~2×122×41.61+5/6+7-9+102×16.42
TG3010-U-0100-150-D115v~2×152×33.31+5/6+7-9+102×20.52
TG3010-U-0100-180-D115v~2×182×27.71+5/6+7-9+102×24.62
TG3010-U-0100-240-D115v~2×242×20.81+5/6+7-9+102×32.82
TG3010-U2-0100-060-S2*115v~6166.61+2-4+5/7+98.23
TG3010-U2-0100-090-S2*115v~9111.11+2-4+5/7+912.33
TG3010-U2-0100-120-S2*115v~1283.31+2-4+5/7+916.43
TG3010-U2-0100-150-S2*115v~1566.61+2-4+5/7+920.53
TG3010-U2-0100-180-S2*115v~1855.51+2-4+5/7+924.63
TG3010-U2-0100-240-S2*115v~2441.61+2-4+5/7+932.83
TG3010-U2-0100-060-D2*115v~2× 62×83.31+2-4+5/6+7-9+102×8.24
TG3010-U2-0100-090-D2*115v~2× 92×55.51+2-4+5/6+7-9+102×12.34
TG3010-U2-0100-120-D2*115v~2×122×41.61+2-4+5/6+7-9+102×16.44
TG3010-U2-0100-150-D2*115v~2×152×33.31+2-4+5/6+7-9+102×20.54
TG3010-U2-0100-180-D2*115v~2×182×27.71+2-4+5/6+7-9+102×24.64
TG3010-U2-0100-240-D2*115v~2×242×20.81+2-4+5/6+7-9+102×32.84







Tags


EI30/10.5 1.0VA, Safety transformer/Short-circuit-proof, Vacuum Filled Casting, Split Bobbin Design, Temperature Class ta 70°C/B, Dielectric Strength 4500Vrms, Weight:70grams





Address : E13, Star Park Enterprises Zone, No.198, Ming Zhu Avenue, High-tech Zone, Hefei, 230088, China
86-18654187233
sales@tigermagnetics.com
Skype

© 2008-2021 Anhui Tiger Magnetics Co. Ltd. All Rights Reserved. / 皖ICP备13000124号-1
All content included on this site is the property of Anhui Tiger Magnetics Co. Ltd. or its content suppliers and protected by international copyright laws.